Honeywell vista-128bpt vista-250bpt alarm control host
Vista-128bpt / 250bpt product features and advantages
Performance features and ordering information
basic function
Provide 9 wired defense areas
Through the built-in polling loop interface (v-plex?, multiplex), vista-128bpt can expand up to 119 defense zones, and vista-250bpt can expand 241 defense zones
Support up to 127 wireless defense area expansion, and use up to two 5800 series wireless receivers. (when the extended zone of wired zone / polling loop is used, the wireless zone will be less than 127)
Alarm output circuit: 12VDC, maximum output current 1.7A
It can be divided into 8 independent control subsystems
Provide 150 user codes in 7 levels
Provide 32 keyboard macro instructions with a maximum of 32 characters per command
Time log, vista-128bpt can save 512 event records, vista-250bpt can save 512 event records
1000 time records
Defense zone 1 supports up to 16 2-wire smoke detectors
Defense zone 7 can be used as a key cloth arming switch
Integrated win-pak access control system can provide more users, event reports and schedule control
The vistakey access control system supports v-plex expansion, in which vista-128bpt supports 8 vistakey modules (access points) and 250 access cards, and vista-250bpt supports 15 vistakey modules (access points) and 500 access cards
It can be easily programmed and maintained by using the download software compass based on Windows system
Support up to 96 programmable output devices
The smoke detector can be reset by keyboard
Rapid deployment
· group bypass
Compulsory deployment
· incident deployment
Support carbon monoxide (CO) zone type
Provide enhanced high-speed RS-232 interface for third-party interface and automation equipment
Expansion of IP communication equipment through ECP bus of host
Support v-plex intelligent connection function, which can improve the response speed of v-plex defense area.
Telephone disconnection monitoring
Additional features
Basic wired defense zone characteristics:
* tail resistance monitoring (optional for zone 2-8) supports normally open and normally closed detectors
The limited defense area can be configured to any one of the eight subsystems
Defense zone 1 supports up to 16 2-wire smoke detectors
· 4-wire smoke detector and temperature detector in zone 1-8 (EOL monitoring is required for use with 4-wire smoke detector) can only be used for residential fire alarm
Characteristics of rotation training loop extension (v-plex?) bus defense area:
Maximum loop current up to 128ma
· v-plex equipment must be used
It is monitored by the host computer
It can be configured to any of the 8 subsystems separately
Support VSI bus isolation module
Support 4297 expansion module
Maximum line length 3600 m (12000 ft)
Wireless extended defense zone features:
Up to 2 series of wireless receivers can be connected. Vista-128bpt supports up to 127 wireless defense zones, and vista-250bpt supports 241 at most
Wireless defense area (if wired defense area and / or bus are used to expand defense area, the number of wireless defense area will be reduced)
· the host monitors wireless devices (except for some non monitored transmitters) via a "check-in" signal
· provide tamper protection for monitored transmitters
It can be configured to any one of the eight subsystems
Schedule features:
· withdrawal / deployment schedule (for control of deployment / withdrawal and reporting)
· holiday schedule (allow different time windows to withdraw / deploy)
Timing events (such as activation of relay, automatic bypass and cancellation of bypass, automatic deployment / deployment, etc.)
· access schedule (e.g. limiting the time users can access the system)
· end user output programming mode (20 time periods for output control)
Subsystem characteristics:
It can provide 8 subsystems which are controlled independently
· public area subsystem, which can be programmed to automatically deploy the public area subsystem after the last subsystem is deployed, and automatically withdraw the public area subsystem after any subsystem is withdrawn.
The main subsystem (9) is assigned to the main keyboard to view the status of all eight subsystems simultaneously on the main keyboard
All defense zones can be assigned to one of the eight subsystems
The keyboard can be assigned to one of the eight subsystems or configured to the primary subsystem (9) to view system status
It can assign relays to one or all eight subsystems
* display fire and / or theft alarms and emergency and environmental faults on the keyboards of all subsystems (optional)
The number of users, entry delay and exit delay can be programmed individually for each subsyste
ordering information
Technical parameters of vista-128bpt / 250bpt
technical parameter
Model: vista-128bpt
Specifications
Electrical specifications
Input voltage: ~ 220 V, 50 Hz, using 1361 transformer (16.5 VAC, 40 VA)
Alarm output: 10vdc-13.8vdc, maximum 1.7A; auxiliary current consumption is less than 750ma
Backup battery: 12VDC, 7Ah sealed lead-acid battery
Standby time: Minimum 4 hours with 7Ah battery for 750ma auxiliary loading
Circuit protection: PTC circuit breaker is adopted at battery input terminal, alarm output terminal and auxiliary power supply end to prevent battery reverse connection or other wiring errors (such as short circuit)
Communication format:
· Ademco contact ID and Ademco 4 + 2 express for 4 and 10 digit accounts
1 6. 5 VAC, 25VA transformer
Dimensions:
Host 318mm (W) x 368mm (H) x 76mm (d)
6160 keyboard 189mm (W) x 133mm (H) x 33mm (d)
parts
Auxiliary equipment · 6160 - alpha keyboard
6148ch - Chinese fixed character keyboard
· 4204 - relay module, 4 type C contacts
• 4232AP